Answer: A
Before the end point, highly mobile HX+ ions (λ∘≈350) are replaced by less mobile NaX+ ions (λ∘≈50), so conductance falls. At the end point only NaCl is present and conductance is minimum. Beyond it, excess NaX+ and highly mobile OHX− (λ∘≈198) accumulate, so conductance rises sharply. The curve is V-shaped.