Topic 10 of 16

Iodometric and iodimetric titrations by equivalents notes

These Iodometric and iodimetric titrations by equivalents notes explain the idea step by step, with 4 worked examples and ten questions with solutions. After this topic you will be able to solve iodine titrations in one line of milliequivalents, use the iodine set free as the carrier of equivalents for copper(II), dichromate, hydrogen peroxide, ozone and bleaching powder, and count potassium iodate correctly.

Why iodine is used as a go-between

In a relay race the baton passes from the first runner to the second and then to the third. The baton does not change on the way. Many oxidants, such as , bleaching powder or , give no sharp end point of their own. So they are made to hand their oxidising power to iodine: added to excess KI, they set free . Iodine gives a deep blue colour with starch, so it is easy to titrate with sodium thiosulfate. The baton here is the equivalents. Topic 11 of the Redox Reactions chapter covers the practical side (starch, conditions) and works by mole ratios. Here every sum is one line of milliequivalents.

Iodine and thiosulfate in equivalents

The one reaction behind every sum is . One takes 2 electrons, so and . One thiosulfate ion gives 1 electron, so and hypo, , has (Topic 4). With (Topic 6), a thiosulfate solution has and an iodine solution has .

meq of iodine = meq of thiosulfate at the end point. V in mL.
Iodimetry (direct method)
A standard iodine solution is the titrant. It measures reducing agents such as thiosulfate, sulfite, and arsenic(III).
Iodometry (indirect method)
An oxidising agent is added to excess KI. The iodine set free is titrated with standard thiosulfate.
The two iodine methods. In iodimetry iodine itself is the titrant. In iodometry the oxidant first sets iodine free from excess KI, and thiosulfate then titrates that iodine.

Iodometry: iodine carries the equivalents

Step 1: the oxidant takes x meq of electrons from . Every 2 electrons lost by iodide make one , so x meq of form. Step 2: this iodine takes x meq of electrons back from thiosulfate. KI is in excess, so its amount is not needed.

The oxidant is counted with its n-factor in the reaction with iodide. Thiosulfate: meq = N x V(mL). One oxidant needs care: , because its own iodine atom also ends up in the (see the section on potassium iodate below).
Iodine as the carrier. The electrons the oxidant takes from iodide in step 1 are exactly the electrons thiosulfate gives back to iodine in step 2.
OxidantStep 1 with excess KInEquivalent mass
163.5 (Cu); 249.5 ()
, acid649
, acid531.6
, acid217
Ozone, 224
Available chlorine235.5
, acid5 in step 1; 6 to the end of the titration (see below) against thiosulfate

Copper goes only from to , because it ends as solid CuI. So , not 2. In ozone only one O atom is reduced (0 to ); the other two leave as . So . The reaction of with iodide is slow, and a little ammonium molybdate is added as a catalyst.

Bleaching powder contains hypochlorite, which with acid can give chlorine. Its available chlorine is the mass of that 100 g of the powder can give. In the flask, sets free the same iodine as that chlorine would. So meq of thiosulfate = meq of available , with .

Potassium iodate: is the n-factor 5 or 6?

Look at step 1 alone: . Iodine in goes from to 0, so one takes 5 electrons. In this reaction . This is the right number for a question about this reaction only, such as how much KI one mole of uses up (5 mol).

Now count the iodine set free. The 3 hold 6 iodine atoms: 5 came from iodide and 1 from the iodate itself. Thiosulfate turns all 6 into , and that needs 6 electrons: 3 mol of is equivalents. So 1 mmol of always calls for 6 meq of thiosulfate.

The electron account of one iodate ion. Its own iodine atom falls 5 steps in step 1 and 1 more step in step 2. The thiosulfate used matches the full fall of 6.

Where does the sixth electron come from? Follow the iodine atom of iodate to the end of the titration. It falls from to 0 in step 1 and from 0 to in step 2. Overall becomes and takes 6 electrons. Books that give and for in iodometry count this whole journey. The relay rule assumed that all the iodine was made from iodide. Here one atom in six was not, so the count of step 1 (5) and the count of thiosulfate (6) differ.

Two safe ways to handle KIO3
  1. 1Step-by-step way: use the equation. mmol of mmol of ; meq of mmol of ; this equals the meq of thiosulfate.
  2. 2Overall way: take for () and write meq of = meq of thiosulfate directly.
  3. 3Both give meq of thiosulfate mmol of . Use one way all through and never mix them.
Common mistake
Never write meq of (with ) = meq of thiosulfate. That mixes the count of step 1 with the count of step 2 and gives a thiosulfate volume that is only 5/6 of the true one.
How to solve an iodometry problem by equivalents
  1. 1meq of thiosulfate = N x V(mL). For thiosulfate N = M.
  2. 2This is the meq of the oxidant in the portion taken. Apply the aliquot factor if needed.
  3. 3Mass in mg = meq x E, with E of the oxidant from the table. Then find the percentage or the concentration.
How to solve an iodimetry problem by equivalents
  1. 1Find the n-factor of the reductant with iodine (electrons it gives) and its equivalent mass.
  2. 2Write meq of iodine = meq of reductant, with meq of iodine = N x V(mL) and N = 2M for iodine.
Worked example 1: standardising iodine with arsenic(III) oxide (iodimetry)

0.1485 g of pure (198) is dissolved in dilute NaOH and the solution is buffered with . It needs 24.0 mL of an iodine solution: (the removes the formed). Find the normality, the molarity and the strength in g/L of the iodine solution.

  1. 1Each As goes from to (arsenate, ) and there are two As atoms, so and (Topic 4).
  2. 2meq of = meq of iodine.
  3. 3, so . Molarity .
  4. 4Strength .
  5. 5Mole check: mmol of needs mmol of in 24.0 mL, that is 0.0625 M. Same answer.
Answer: 0.125 N; 0.0625 M; 15.9 g/L
Worked example 2: potassium iodate counted both ways

0.0749 g of pure (214) is dissolved in water. Excess KI and dilute are added. The iodine set free needs 28.0 mL of a thiosulfate solution. Find the normality of the thiosulfate.

  1. 1mmol of .
  2. 2Step-by-step way: mmol of . meq of = meq of thiosulfate.
  3. 3Overall way: . meq of = meq of thiosulfate.
  4. 4Both ways: , so (also 0.0750 M).
  5. 5The wrong mix: gives meq and , too small by the factor 5/6.
Answer: 0.0750 N thiosulfate
Worked example 3: purity of blue vitriol

2.495 g of impure (249.5) is dissolved and made up to 200 mL. 20.0 mL of the solution is treated with excess KI. The iodine set free needs 15.0 mL of 0.0600 N thiosulfate. The impurity does not react. Find the percentage purity.

  1. 1meq of thiosulfate = meq of in 20.0 mL.
  2. 2Whole solution: meq.
  3. 3 goes to CuI, so and . Mass .
  4. 4Purity .
  5. 5Mole check: 0.900 mmol of thiosulfate means 0.450 mmol of , which came from mmol of . Same count.
Answer: 90.0% pure
Worked example 4: available chlorine in bleaching powder

1.775 g of bleaching powder is shaken with water and made up to 250 mL. 25.0 mL of the suspension is treated with excess KI and acetic acid. The iodine set free needs 15.0 mL of 0.100 N thiosulfate. Find the percentage of available chlorine. ( = 71)

  1. 1meq of thiosulfate = meq of available in 25.0 mL.
  2. 2Whole sample: meq.
  3. 3 of . Mass of available chlorine .
  4. 4Percentage .
Answer: 30.0% available chlorine
How much thiosulfate one millimole of each oxidant calls for. Copper(II) needs the least, iodate and dichromate the most.
Common mistake
Two n-factors are often taken wrong. Copper(II) in iodometry is 1, not 2, because the product is copper(I) iodide. Iodine is 2, so a 0.0500 M iodine solution is 0.100 N. Only for thiosulfate are molarity and normality equal.
Tip
Because thiosulfate has , its meq are also its millimoles, and they equal the millimoles of electrons the oxidant took. Harder cases, such as mixed with KI, are in Topic 16 of this chapter.
Key points
  • : iodine has n = 2 (E = 127), thiosulfate has n = 1 (E = 248 for hypo).
  • Iodimetry: standard iodine titrates a reductant; meq of iodine = meq of reductant.
  • Iodometry: meq of oxidant = meq of iodine set free = meq of thiosulfate. Excess KI is never counted.
  • n-factors: 1; , and available 2; (acid) 5; 6.
  • : 5 electrons in its reaction with iodide, but 6 meq of thiosulfate per mmol, because 3 are set free. Use the equation, or () overall. Never use 5 against thiosulfate.
  • Available chlorine % = meq of thiosulfate x 35.5 mg / mass of sample in mg x 100.

Ten Iodometric and iodimetric titrations by equivalents questions

Try each one on paper first, then open the answer and the worked solution under it.

1Starter
In the reaction , the equivalent masses of (254 g/mol) and of (248 g/mol) are
  1. A254 and 248
  2. B127 and 124
  3. C127 and 248
  4. D254 and 124
Show answer and solution

Answer: C

One takes 2 electrons, so and . Two thiosulfate ions give 2 electrons between them, so each gives 1: and . 124 comes from taking for thiosulfate, and 254 from taking for iodine.
2Starter
20.0 mL of an iodine solution needs 25.0 mL of 0.0400 N sodium thiosulfate to reach the starch end point. The mass of (254 g/mol) in one litre of the iodine solution is
  1. A6.35 g
  2. B12.7 g
  3. C4.06 g
  4. D3.18 g
Show answer and solution

Answer: A

, so the iodine solution is 0.0500 N. of . Strength . 12.7 g uses . 4.06 g inverts the volume ratio (). 3.18 g halves the answer once more.
3Starter
0.245 g of (294 g/mol) is added to excess KI and dilute : . How many milliequivalents of iodine are set free?
  1. A0.833
  2. B2.50
  3. C10.0
  4. D5.00
Show answer and solution

Answer: D

has , so . meq of dichromate . meq of iodine set free = meq of oxidant = 5.00. 0.833 is the millimoles of dichromate and 2.50 is the millimoles of . 10.0 doubles the answer.
4Starter, numerical answer
Excess KI is added to a copper(II) sulfate solution: . The iodine set free needs 24.0 mL of 0.0500 N sodium thiosulfate. Find the mass of copper in the solution. (Cu = 63.5) Give the answer in mg to one decimal place.

Numerical answer, in mg.

Show answer and solution

Answer: 76.2 mg (accepted range 76.15 to 76.25)

meq of thiosulfate = meq of . Copper goes from to , so and . Mass .
5Exam level
0.0535 g of pure (214 g/mol) is treated with excess KI and dilute : . What volume of 0.0500 N sodium thiosulfate is needed for the iodine set free?
  1. A25.0 mL
  2. B30.0 mL
  3. C15.0 mL
  4. D5.0 mL
Show answer and solution

Answer: B

mmol of . It sets free mmol of , which is meq. meq of thiosulfate = 1.50, so . The overall count gives the same: , meq. 25.0 mL uses against thiosulfate. 15.0 mL forgets that one is 2 equivalents. 5.0 mL takes .
6Exam level
0.710 g of bleaching powder is treated with excess KI and acetic acid. The iodine set free needs 25.0 mL of 0.200 N sodium thiosulfate. The percentage of available chlorine in the sample is ( = 71)
  1. A50.0%
  2. B12.5%
  3. C44.7%
  4. D25.0%
Show answer and solution

Answer: D

meq of thiosulfate = meq of available . of . Mass . Percentage . 50.0% uses . 12.5% halves the meq. 44.7% is the percentage of (127 g/mol, ), not of available chlorine.
7Exam level
10.0 mL of a hydrogen peroxide solution is added to excess acidified KI (with a little ammonium molybdate as catalyst): . The iodine set free needs 28.0 mL of 0.250 N sodium thiosulfate. The strength of the hydrogen peroxide solution is ( = 34)
  1. A23.8 g/L
  2. B11.9 g/L
  3. C5.95 g/L
  4. D3.92 g/L
Show answer and solution

Answer: B

meq of thiosulfate = meq of in 10.0 mL. Normality . As an oxidant takes 2 electrons, so . Strength . 23.8 uses . 5.95 divides by 2 twice. 3.92 is the volume strength (), not the strength in g/L.
8Exam level, numerical answer
500 mL (measured at STP) of ozonised oxygen is passed through neutral KI solution: . The solution is acidified, and the iodine needs 15.0 mL of 0.100 N sodium thiosulfate. Find the volume of ozone, at STP, in the gas sample. (Molar volume at STP ) Give the answer in mL to one decimal place.

Numerical answer, in mL.

Show answer and solution

Answer: 16.8 mL (accepted range 16.75 to 16.85)

meq of thiosulfate = meq of ozone. One takes 2 electrons (one O atom goes from 0 to ), so . mmol of ozone . Volume . This is 3.36% of the 500 mL sample. Taking (all three O atoms) would give only 5.6 mL.
9Challenge
A student wants a 0.100 N solution of (214 g/mol) for iodometry. He takes the n-factor as 5 and dissolves g in one litre. 25.0 mL of this solution is treated with excess KI and dilute (), and the iodine is titrated with 0.100 N sodium thiosulfate. What volume of thiosulfate is used?
  1. A25.0 mL
  2. B20.8 mL
  3. C15.0 mL
  4. D30.0 mL
Show answer and solution

Answer: D

Molarity of the solution . 25.0 mL holds 0.500 mmol of . This sets free mmol of meq, so 30.0 mL of 0.100 N thiosulfate is used. The student expected 25.0 mL, because with the 25.0 mL holds 2.50 meq. But the iodine set free carries 6 equivalents per mole of iodate, so toward thiosulfate the solution is . 20.8 mL multiplies 25.0 by 5/6 in place of 6/5. 15.0 mL counts one as one equivalent.
10Challenge, numerical answer
A thiosulfate solution is standardised first: 0.1605 g of pure (214 g/mol), with excess KI and dilute , sets free iodine that needs 36.0 mL of the thiosulfate. Then 1.524 g of a copper-nickel coin alloy is dissolved, all the copper is brought to and the solution is made up to 250 mL. 25.0 mL of it, with excess KI, needs 14.4 mL of the same thiosulfate. The nickel does not react with KI. Find the percentage of copper in the alloy. (Cu = 63.5) Give the answer to one decimal place.

Numerical answer, in %.

Show answer and solution

Answer: 75 % (accepted range 74.95 to 75.05)

Standardisation: mmol of . By it sets free 2.25 mmol of meq (or overall: ). So and . Copper: meq of thiosulfate = meq of in 25.0 mL. Whole solution: meq. Copper has (), so . Mass . Percentage . Using for against thiosulfate would give 62.5%.