Topic 5 of 14

Conductance of electrolytic solutions notes

These Conductance of electrolytic solutions notes explain the idea step by step, with 5 worked examples and ten questions with solutions. After this topic you can turn a measured resistance into conductance and conductivity, find and use a cell constant, read a Wheatstone bridge, and explain what changes the conductivity of a solution.

Why we need a number for how well a solution conducts

Pure water carries almost no current. Add a pinch of salt and it conducts well; add sugar and it does not. So ions carry the charge. We want one number for how well a solution conducts that belongs to the solution, not to the vessel. A long, thin pipe lets little water through and a short, wide one lets much through: the shape of the vessel matters as well as what is inside. We must separate the two.

Metallic conduction and electrolytic conduction

In a metal, electrons drift through the fixed lattice of metal ions and nothing chemical happens. Heating makes the metal atoms vibrate more and get in the way of the electrons, so a metal conducts less when hot. In a solution of , ions carry the charge: cations move to the negative electrode, anions to the positive one. At the electrodes they gain or lose electrons, so a chemical change happens there (electrolysis, Topic 8). A heated solution is less viscous and its ions move faster, so an electrolyte conducts more when hot. Solid conductors and semiconductors are covered in Topic 10 of the Solid State chapter.

Left: electrons drift along a wire. Right: in a solution, cations move to the cathode and anions to the anode, and the charge changes hands at the electrodes.
FeatureMetallic conductionElectrolytic conduction
Charge carrierselectronscations and anions
Matter moves?noyes, ions move through the solution
Chemical changenoneat the electrodes
On heating, conductivitydecreasesincreases

Resistance and resistivity

Ohm's law says ; the resistance is in ohm (). Picture a column of solution between two flat electrodes. Make it twice as long and the ions travel twice as far: the resistance doubles. Make it twice as wide (double the area) and there are twice as many paths side by side: the resistance halves. So is proportional to the length and inversely proportional to the area . The constant of proportionality is called the resistivity, (rho).

is the distance between the electrodes, is the area of each electrode, is the resistivity of the material.
Resistivity
The resistivity of a material is the resistance of a piece of it of unit length and unit area of cross-section, for example a cube of side 1 m. It depends only on the material (and the temperature), not on its shape.

Units: from , the unit is in SI. Many books also use . Since , .

Conductance and conductivity

Chemists prefer to ask how easily current passes, not how hard. So we turn both quantities upside down. The reciprocal of resistance is conductance, and the reciprocal of resistivity is conductivity.

Conductance
Conductance . Its SI unit is the siemens, S, where (older books write ohm or mho).
Conductivity (specific conductance)
Conductivity (kappa). It is the conductance of a cube of the material of side 1 m (or 1 cm). Its SI unit is ; the common non-SI unit is .
Turn upside down and write for .
Common mistake
Unit trap: , not . Reason: means per centimetre, and there are 100 centimetres in a metre, so a number per cm becomes 100 times bigger per m. Check with real data: 0.100 M KCl has .
QuantitySymbol and relationSI unitCommon unit
Resistance
Resistivity
ConductanceSS
Conductivity
Cell constant

The conductivity cell and the cell constant

The vessel that holds the solution is a conductivity cell: two platinum plates coated with finely divided platinum (platinum black), held a fixed distance apart. For one cell, and never change, so is a fixed number, the cell constant . Putting it into gives the working relation below. The current spreads beyond the plate edges, so a ruler does not give accurately. Instead the cell is calibrated: fill it with a KCl solution of accurately known conductivity, measure , and use .

A conductivity cell. The cell constant is the distance between the plates divided by the area of one plate.
belongs to the cell; belongs to the solution; is what you measure.
KCl concentration () () ()
1.0000.111311.13
0.1000.01291.29
0.0100.001410.141

Conductivity of KCl solutions at 298.15 K (NCERT Class 12, Electrochemistry). These standard solutions are used to calibrate a cell. Conductivity falls on dilution because fewer ions per unit volume carry the current. Molar conductivity is the subject of Topic 6.

How to find the conductivity of an unknown solution
  1. 1Fill the cell with a standard KCl solution of known and measure its resistance .
  2. 2Cell constant: . Keep the length unit the same as in ( with , with ).
  3. 3Fill the rinsed cell with the unknown solution; measure .
  4. 4Conductivity: . Convert units at the end if the question asks.
  5. 5Short cut for the same cell: , because both products equal .

Measuring the resistance of a solution

Why not use a battery and an ammeter? A direct current (DC) pushes the ions one way only, so products of electrolysis pile up at the electrodes. Gas covers the plates and the electrodes act like a small cell that opposes the current (polarisation). The reading drifts. So an alternating current (AC) in the audio range is used (NCERT: 550 to 5000 cycles per second). It reverses many times a second, so a change made in one half-cycle is undone in the next. The platinum black coating helps by giving the plates a large surface.

The resistance is found with a Wheatstone bridge. Four resistances form a loop A-B-C-D: (A to B), (B to C), a variable resistance (A to D) and the conductivity cell (D to C). The AC source is connected across A and C, and a detector (headphones or an electronic detector) across B and D. is changed until the detector shows no current. Then B and D are at the same potential, the bridge is balanced, and .

Wheatstone bridge in outline. At balance no current flows through the detector between B and D.
Valid only at balance, with the arms placed as in the figure. Always check which arm is opposite which; the cell's arm and meet at D. NCERT names the arms differently and writes ; the rule is the same: at balance, the two arms on one side of the detector are in the same ratio as the two arms on the other side.

What decides the conductivity of a solution

Conductivity is high when there are many ions per unit volume, with large charges, moving fast. (1) Nature of the electrolyte: HCl is fully ionised, acetic acid only slightly, so 0.1 M HCl has but 0.1 M acetic acid only (NCERT). (2) Size of the ions and their solvation: an ion drags a shell of water with it, and a bigger moving unit is slower. (3) Nature and viscosity of the solvent: a thick solvent slows every ion. (4) Concentration: fewer ions per unit volume, so falls on dilution. (5) Temperature: a warmer solution is less viscous, ions move faster and rises, so a conductivity is always quoted with its temperature.

Conductivities at 298.15 K on a log scale (NCERT values). Pure water conducts about 4000 times less than 0.01 M KCl; glass and Teflon are insulators.
Tip
Quick checks. A bigger resistance in the same cell means a smaller conductivity. For salt solutions from about 0.001 M to 1 M, lies roughly between and ; if you get , or and below, for an ordinary salt solution, look for a factor-of-100 unit slip.
Common mistake
The cell constant belongs to the cell. Once known, it is the same for every solution put into that cell; do not recalculate it from the new resistance. Only changing or changes . Conductivity belongs to the solution: a different cell changes , not .

Worked examples

Worked example 1: from the shape of the cell

Suppose a cell has plates of area placed apart. Filled with a salt solution, its resistance is . Find (a) the conductance, (b) the cell constant, (c) the conductivity in and in .

  1. 1(a) .
  2. 2(b) .
  3. 3(c) .
  4. 4To SI: multiply by 100, so .
Answer: , , .
Worked example 2: calibrating a cell with KCl

A cell filled with 0.100 M KCl ( at 298 K, NCERT) shows a resistance of (suppose). The same cell filled with solution X shows . Find the cell constant and the conductivity of X.

  1. 1Cell constant: (siemens times ohm cancel). In cm units this is .
  2. 2For X: .
  3. 3Check by the short cut: . Six times the resistance, one sixth the conductivity.
Answer: ; .
Worked example 3: from resistivity to resistance

Suppose a solution has resistivity . What resistance will it show in a cell with plates apart, each of area ? What is its conductivity in ?

  1. 1.
  2. 2.
  3. 3In SI: . (Or: , and .)
Answer: ; .
Worked example 4: reading a Wheatstone bridge

Suppose a conductivity cell of cell constant sits in the arm D-C of a Wheatstone bridge (arms as in the figure above). With and , the detector shows no current when . Find the conductivity of the solution.

  1. 1At balance , so .
  2. 2.
  3. 3In SI: .
Answer: , .
Worked example 5: predicting a resistance in the same cell

Suppose a cell shows when filled with 0.010 M KCl. What resistance will it show with 1.000 M KCl? Use = 0.141 and for the two solutions (NCERT, 298 K).

  1. 1Cell constant: .
  2. 2For 1.000 M KCl: .
  3. 3Sense check: . 100 times more KCl gives only times more conductivity; Topic 6 explains why.
Answer: About .
Key points
  • Metals conduct by electrons with no chemical change and conduct less when hot; electrolyte solutions conduct by moving ions, with chemical change at the electrodes, and conduct more when hot.
  • ; conductance (S); conductivity ( or ); .
  • Cell constant , found by calibration with standard KCl; then for any solution in that cell.
  • Resistance of a solution is measured with AC (to avoid electrolysis and polarisation) on a Wheatstone bridge: at balance .
  • Conductivity rises with the number of ions per unit volume, their charge and their speed: strong electrolyte, higher concentration, smaller solvated ions, less viscous solvent, higher temperature.

Ten Conductance of electrolytic solutions questions

Try each one on paper first, then open the answer and the worked solution under it.

1Starter
A solution is placed in a conductivity cell and four quantities are found. Which one depends only on the cell (the distance between its plates and their area) and not on the solution inside it?
  1. AConductivity
  2. BConductance
  3. CCell constant
  4. DResistivity
Show answer and solution

Answer: C

The cell constant is : a distance divided by an area. Both belong to the cell, so stays the same whatever solution is put in. Conductivity and resistivity belong to the solution only: they do not change if the same solution is moved to another cell. Conductance depends on both the solution and the cell. Answer: the cell constant.
2Starter
The conductivity of a solution is . What is it in ?
  1. A
  2. B
  3. C
  4. D
Show answer and solution

Answer: A

means siemens per centimetre. One metre holds 100 cm, so the number per metre is 100 times bigger: . Dividing by 100 gives (the most common slip). Multiplying by gives 365 (that factor is for to , not for ). Answer: .
3Starter
The resistance of an electrolyte solution in a conductivity cell is measured with an alternating current (AC), not a direct current (DC). Why?
  1. AAC carries more charge per second through a solution than DC does.
  2. BDC would cause electrolysis at the electrodes; products and polarisation would change the resistance while it is being measured.
  3. CIons cannot move at all in a steady DC field.
  4. DAC makes a weak electrolyte ionise completely, so the reading is larger.
Show answer and solution

Answer: B

With DC the ions always move the same way, so they are discharged at the electrodes: gas collects on the plates, the solution near them changes, and the plates act like a small opposing cell (polarisation). The measured resistance drifts and is wrong. AC reverses many times a second (NCERT: 550 to 5000 cycles per second), so any change in one half-cycle is undone in the next. Ions do move in a DC field (that is electrolysis), and AC does not change the degree of ionisation. Answer: the second option.
4Starter, numerical answer
Suppose a conductivity cell has two parallel plates, each of area , placed apart. Find the cell constant in . Give the answer as an integer.

Numerical answer, in m^-1.

Show answer and solution

Answer: 150 m^-1

Cell constant . A number per cm becomes 100 times bigger per m: . (Check in SI from the start: , , .) Answer: 150.
5Exam level
A conductivity cell filled with 1.000 M KCl ( at 298 K, NCERT) shows a resistance of (suppose). The same cell filled with solution Y at 298 K shows . What is the conductivity of Y?
  1. A
  2. B
  3. C
  4. D
Show answer and solution

Answer: D

Step 1, cell constant from the KCl reading: . Step 2, conductivity of Y in the same cell: . Step 3, to SI: . Check with the short cut : . Wrong options: is the value in with the unit not converted; divides by 100 instead of multiplying; 413 uses the resistance ratio upside down (). Answer: .
6Exam level
Suppose solution Z shows a resistance of in cell 1, whose plates are apart and each of area . The same solution, at the same temperature, is put into cell 2, whose plates are apart and each of area . What resistance does cell 2 show?
  1. A
  2. B
  3. C
  4. D
Show answer and solution

Answer: D

The solution is the same, so its conductivity is the same; only the cell constant changes. Step 1: and , so cell 2 has twice the cell constant. Step 2: , so is proportional to : . Wrong options: 540 uses only the longer distance () and forgets the smaller area; 480 uses only the smaller area (); 180 turns the ratio upside down. Answer: .
7Exam level
Suppose solution P shows in a cell of cell constant , and solution Q shows in another cell of cell constant , both at 298 K. Which solution has the higher conductivity, and by what factor?
  1. AQ, because its resistance is half that of P;
  2. BP;
  3. CP;
  4. DQ;
Show answer and solution

Answer: B

Resistances in two different cells cannot be compared directly, because each cell has its own shape. Turn each into a conductivity, which belongs to the solution alone. Step 1: . Step 2: . Step 3: . So P conducts better, although its resistance is larger. The first option compares resistances only and ignores the cells. The value 4.8 multiplies the two ratios ( and ) instead of dividing. Answer: the second option.
8Exam level, numerical answer
Suppose a Wheatstone bridge has its arms named as in the figure of this topic: A-B, B-C, A-D and D-C, with the AC source across A and C and the detector across B and D. This time the conductivity cell (cell constant ) is placed in arm B-C. The detector shows no current when arm A-B is , arm A-D is and arm D-C is . Find the conductivity of the solution in . Give the answer as an integer.

Numerical answer, in mS m^-1.

Show answer and solution

Answer: 350 mS m^-1

Step 1, balance: B and D are at the same potential, so the arms on each side are in the same ratio: . Step 2, the cell is in arm B-C: . Step 3: . Step 4, units: gives , and gives . Trap: using the formula of the notes without checking the arms gives and a wrong 972. Answer: 350.
9Challenge
Cell A filled with 0.010 M KCl ( at 298 K, NCERT) shows (suppose). Cell A filled with a solution X at 298 K shows . Solution X is then put into cell B, whose plates are each in area and apart. What resistance does cell B show?
  1. A
  2. B
  3. C
  4. D
Show answer and solution

Answer: C

Step 1, cell constant of A: . Step 2, conductivity of X: . Step 3, cell constant of B from its shape: . Step 4: . Wrong options: 50.0 divides by a conductivity in (mixed units); 988 uses instead of ; 2820 assumes the resistance belongs to the solution and does not change with the cell. Answer: .
10Challenge, numerical answer
Suppose a glass tube of inner diameter is filled with 0.100 M KCl ( at 298 K, NCERT). Two flat electrodes close the ends of the tube, so the current flows along the full cross-section. The tube is placed in arm D-C of a Wheatstone bridge (arms as in the figure of this topic), and the detector shows no current when (A-B), (B-C) and (A-D). Find the distance between the electrodes in cm. Take . Give the answer to one decimal place.

Numerical answer, in cm.

Show answer and solution

Answer: 3.9 cm (accepted range 3.85 to 3.95)

Step 1, resistance of the tube: . Step 2, area of cross-section, radius : . Step 3, from : . Step 4: , which is 3.9 to one decimal place. Traps: using the diameter as the radius gives 15.6 cm; using gives 1.5 cm. Answer: 3.9.