Difficulty 1 of 3
mt168
During the electrolytic refining of copper, pure copper is deposited on
A
the cathode, which is a thin sheet of pure copper
B
the walls of the tank
C
the anode, which is a block of impure copper
D
both electrodes equally
Answer: A
Impure copper is the anode and dissolves as
Cu
X
2
+
. These ions are reduced at the cathode (pure copper strip), where pure copper is deposited.