JEE Main physics PYQ, Experimental Physics

Vernier callipers: JEE Main PYQ with Solutions

24 questions on Vernier callipers from the Experimental Physics chapter, newest first. Open "Show answer and solution" under a question to check your work.

By Sunil Kumar. Updated 26 November 2026.

All 24 questions

JEE Main 202605 Apr Shift 1

Single correct optionMarks +4, -1
In a Vernier calipers, when both jaws touch each other, zero of the Vernier scale is shifted to the right of zero of the main scale and Vernier division coincides with a main scale reading. If the value of 1 main scale division is and there are 10 Vernier scale divisions, then the Vernier caliper has
  1. A negative zero error
  2. B negative zero error
  3. C positive zero error
  4. D positive zero error
Show answer and solution

Answer: (C)

Least count . The vernier zero is to the right of the main zero, so the zero error is positive: .

Open question: In a Vernier calipers, when both jaws touch each other...

JEE Main 202628 Jan Shift 1

Single correct optionMarks +4, -1
When both jaws of vernier callipers touch each other, zero mark of the vernier scale is right to zero mark of main scale, mark on vernier scale coincides with certain mark on the main scale. While measuring the length of a cylinder, observer observes 15 divisions on main scale and division of vernier scale coincides with a main scale division. Measured length of cylinder is _____ mm. (Least count of Vernier calliper )
  1. A
  2. B
  3. C
  4. D
Show answer and solution

Answer: (C)

Zero error . With a least count of one main scale division is , so the observed reading is . Length .

Open question: When both jaws of vernier callipers touch each other...

JEE Main 202624 Jan Shift 2

Single correct optionMarks +4, -1
In a vernier callipers, 50 vernier scale divisions are equal to 48 main scale divisions. If one main scale division , then the least count of the vernier callipers is _____ mm.
  1. A
  2. B
  3. C
  4. D
Show answer and solution

Answer: (C)

, so . Least count .

Open question: In a vernier callipers, 50 vernier scale divisions are...

JEE Main 202522 Jan Shift 1

Single correct optionMarks +4, -1
Given below are two statements :
Statement I : In a vernier callipers, one vernier scale division is always smaller than one main scale division.
Statement II : The vernier constant is given by one main scale division multiplied by the number of vernier scale divisions.
In the light of the above statements, choose the correct answer from the options given below.
  1. AStatement I is true but Statement II is false
  2. BStatement I is false but Statement II is true
  3. CBoth Statement I and Statement II are false
  4. DBoth Statement I and Statement II are true
Show answer and solution

Answer: (C)

In the usual vernier one vernier division is a little smaller than a main scale division, but this is not always so: some verniers are made with vernier divisions longer than the main scale divisions. So Statement I, with the word always, is false. The vernier constant is one main scale division divided by the number of vernier divisions, not multiplied by it. So Statement II is false too.

Open question: Given below are two statements : Statement I : In...

JEE Main 202409 Apr Shift 1

Single correct optionMarks +4, -1
One main scale division of a vernier caliper is equal to units. If division of main scale coincides with division of vernier scale, the least count of the vernier caliper is :
  1. A
  2. B
  3. C
  4. D
Show answer and solution

Answer: (C)

, so . Least count .

Open question: One main scale division of a vernier caliper is equal...

JEE Main 202408 Apr Shift 2

Single correct optionMarks +4, -1
Least count of a vernier caliper is . The value of one division on the main scale is . Then the number of divisions of main scale that coincide with divisions of vernier scale is :
  1. A
  2. B
  3. C
  4. D
Show answer and solution

Answer: (C)

Least count . Let main divisions equal vernier divisions, so . Then , which gives .

Open question: Least count of a vernier caliper is (1)/(20N) cm....

JEE Main 202408 Apr Shift 1

Single correct optionMarks +4, -1
The diameter of a sphere is measured using a vernier caliper whose 9 divisions of main scale are equal to 10 divisions of vernier scale. The shortest division on the main scale is equal to . The main scale reading is and second division of vernier scale coincides with a division on main scale. If mass of the sphere is , the density of the sphere is:
  1. A
  2. B
  3. C
  4. D
Show answer and solution

Answer: (A)

Least count . Diameter , radius . Volume . Density .

Open question: The diameter of a sphere is measured using a vernier...

JEE Main 202406 Apr Shift 2

Single correct optionMarks +4, -1
In a vernier calliper, when both jaws touch each other, zero of the vernier scale shifts towards left and its division coincides exactly with a certain division on main scale. If 50 vernier scale divisions equal to 49 main scale divisions and zero error in the instrument is then how many main scale divisions are there in ?
  1. A
  2. B
  3. C
  4. D
Show answer and solution

Answer: (C)

Least count . The key takes the size of the zero error as 4 least counts: , so and . The number of main scale divisions in is .

Open question: In a vernier calliper, when both jaws touch each other...

JEE Main 202405 Apr Shift 2

Single correct optionMarks +4, -1
A vernier callipers has 20 divisions on the vernier scale, which coincides with division on the main scale. The least count of the instrument is . One main scale division is equal to _____ mm.
  1. A
  2. B
  3. C
  4. D
Show answer and solution

Answer: (B)

, so least count . Then and .

Open question: A vernier callipers has 20 divisions on the vernier...

JEE Main 202401 Feb Shift 1

Single correct optionMarks +4, -1
10 divisions on the main scale of a Vernier calliper coincide with 11 divisions on the Vernier scale. If each division on the main scale is of 5 units, the least count of the instrument is :
  1. A
  2. B
  3. C
  4. D
Show answer and solution

Answer: (D)

, so . Least count units.

Open question: 10 divisions on the main scale of a Vernier calliper...

JEE Main 202427 Jan Shift 2

Single correct optionMarks +4, -1
Given below are two statements: one is labelled as Assertion (A) and the other is labelled as Reason (R).
Assertion (A) : In Vernier calliper if positive zero error exists, then while taking measurements, the reading taken will be more than the actual reading.
Reason (R) : The zero error in Vernier Calliper might have happened due to manufacturing defect or due to rough handling.
In the light of the above statements, choose the correct answer from the options given below :
  1. ABoth (A) and (R) are correct and (R) is the correct explanation of (A)
  2. BBoth (A) and (R) are correct but (R) is not the correct explanation of (A)
  3. C(A) is true but (R) is false
  4. D(A) is false but (R) is true
Show answer and solution

Answer: (B)

With a positive zero error the instrument already shows a reading when the jaws are closed, so every reading is more than the true value: (A) is correct. A zero error can come from a manufacturing defect or rough handling: (R) is correct. But (R) tells how a zero error arises, not why a positive one makes readings larger. So (R) is not the explanation of (A).

Open question: Given below are two statements: one is labelled as...

JEE Main 202310 Apr Shift 2

Single correct optionMarks +4, -1
In an experiment with vernier callipers of least count , when two jaws are joined together the zero of vernier scale lies right to the zero of the main scale and division of vernier scale coincides with the main scale division. While measuring the diameter of a spherical bob, the zero of vernier scale lies in between and marks and division of vernier scale coincides with the main scale division. The diameter of bob is measured as
  1. A
  2. B
  3. C
  4. D
Show answer and solution

Answer: (B)

Zero error . Observed reading . Diameter .

Open question: In an experiment with vernier callipers of least count...

JEE Main 202227 Jul Shift 1

Numerical answerMarks +4, no negative
The one division of main scale of vernier callipers reads and 10 divisions of Vernier scale is equal to the 9 divisions on main scale. When the two jaws of the instrument touch each other the zero of the Vernier lies to the right of zero of the main scale and its fourth division coincides with a main scale division. When a spherical bob is tightly placed between the two jaws, the zero of the Vernier scale lies in between and and Vernier division coincides with a main scale division. The diameter of the bob will be _____ .

Numerical answer. Work it out before you open the answer.

Show answer and solution

Answer: 412 (exact integer)

Least count . Zero error . Observed reading . Diameter .

Open question: The one division of main scale of vernier callipers...

JEE Main 202226 Jul Shift 2

Single correct optionMarks +4, -1
In a Vernier Caliper 10 divisions of Vernier scale is equal to the 9 divisions of main scale. When both jaws of Vernier calipers touch each other, the zero of the Vernier scale is shifted to the left of zero of the main scale and Vernier scale division exactly coincides with the main scale reading. One main scale division is equal to . While measuring diameter of a spherical body, the body is held between two jaws. It is now observed that zero of the Vernier scale lies between 30 and 31 divisions of main scale reading and Vernier scale division exactly coincides with the main scale reading. The diameter of the spherical body will be:
  1. A
  2. B
  3. C
  4. D
Show answer and solution

Answer: (C)

Least count . Observed reading . The vernier zero is to the left of the main zero, so the zero error is negative and its size is added. The key takes the zero error as divisions, , which gives . By the usual rule for a negative zero error the size is , which gives ; that value is not offered, and is the nearest choice.

Open question: In a Vernier Caliper 10 divisions of Vernier scale is...

JEE Main 202229 Jun Shift 2

Numerical answerMarks +4, no negative
The Vernier constant of Vernier callipers is and it has zero error of . While measuring diameter of a sphere, the main scale reading is and coinciding vernier division is 5. The corrected diameter will be _____ .

Numerical answer. Work it out before you open the answer.

Show answer and solution

Answer: 180 (exact integer)

Vernier constant . Observed reading . The zero error is subtracted: .

Open question: The Vernier constant of Vernier callipers is 0.1 mm...

JEE Main 202226 Jun Shift 1

Numerical answerMarks +4, no negative
In a vernier callipers, each cm on the main scale is divided into 20 equal parts. If tenth vernier scale division coincides with ninth main scale division. Then the value of vernier constant will be _____

Numerical answer. Work it out before you open the answer.

Show answer and solution

Answer: 5 (exact integer)

One main scale division . Since 10 vernier divisions equal 9 main divisions, the vernier constant is .

Open question: In a vernier callipers, each cm on the main scale is...

JEE Main 202131 Aug Shift 2

Numerical answerMarks +4, no negative
The diameter of a spherical bob is measured using a vernier callipers. 9 divisions of the main scale, in the vernier callipers, are equal to 10 divisions of vernier scale. One main scale division is . The main scale reading is and division of vernier scale was found to coincide exactly with one of the main scale division. If the given vernier callipers has positive zero error of , then the radius of the bob is ____________ .

Numerical answer. Work it out before you open the answer.

Show answer and solution

Answer: 52 (exact integer)

Least count . Observed diameter . The positive zero error, , is subtracted: . Radius .

Open question: The diameter of a spherical bob is measured using...

JEE Main 202117 Mar Shift 1

Single correct optionMarks +4, -1
The vernier scale used for measurement has a positive zero error of . If while taking a measurement it was noted that 0 on the vernier scale lies between and . Vernier coincidence is 6, then the correct value of measurement is _____ cm. (least count )
  1. A
  2. B
  3. C
  4. D
Show answer and solution

Answer: (B)

Observed reading . The positive zero error, , is subtracted: .

Open question: The vernier scale used for measurement has a positive...

JEE Main 202116 Mar Shift 1

Single correct optionMarks +4, -1
One main scale division of a vernier callipers is cm and division of the vernier scale coincide with division of the main scale. The least count of the callipers in mm is :
  1. A
  2. B
  3. C
  4. D
Show answer and solution

Answer: (D)

vernier divisions equal main divisions, so one vernier division is cm. Least count cm mm.

Open question: One main scale division of a vernier callipers is a cm...

JEE Main 202006 Sep Shift 2

Single correct optionMarks +4, -1
A student measuring the diameter of a pencil of circular cross-section with the help of a vernier scale records the following four readings , , , . The average of these four reading is and the standard deviation of the data is . The average diameter of the pencil should therefore be recorded as :
  1. A
  2. B
  3. C
  4. D
Show answer and solution

Answer: (D)

The readings are taken to , so the result cannot be quoted more finely than that. The mean is rounded to two decimal places, , and the spread to the same place, . The record is .

Open question: A student measuring the diameter of a pencil...

JEE Main 202002 Sep Shift 1

Single correct optionMarks +4, -1
The least count of the main scale of a vernier calipers is . Its vernier scale is divided into 10 divisions and coincide with 9 divisions of the main scale. When jaws are touching each other, the division of the vernier scale coincides with a division of the main scale and the zero of vernier scale is lying right side of the zero of the main scale. When this vernier is used to measure the length of the cylinder the zero of the vernier scale between and and VSD coincides with the main scale division. The length of the cylinder is (VSD is vernier scale division)
  1. A
  2. B
  3. C
  4. D
Show answer and solution

Answer: (C)

Least count . The vernier zero is to the right of the main zero, so the zero error is positive: . Observed reading . Length .

Open question: The least count of the main scale of a vernier calipers...

JEE Main 201510 Apr

Single correct optionMarks +4, -1
Diameter of a steel ball is measured using a Vernier calipers which has divisions of on its main scale (MS) and 10 divisions of its Vernier scale (VS) match 9 divisions on the main scale. Three such measurements for a ball are given as:
S.No. 1: MS , VS divisions 8
S.No. 2: MS , VS divisions 4
S.No. 3: MS , VS divisions 6
If the zero error is , then mean corrected diameter is:
  1. A
  2. B
  3. C
  4. D
Show answer and solution

Answer: (C)

Least count . The three readings are , and ; their mean is . The zero error is subtracted: .

Open question: Diameter of a steel ball is measured using a Vernier...

JEE Main 201406 Apr

Single correct optionMarks +4, -1
A student measured the length of a rod and wrote it as . Which instrument did he use to measure it ?
  1. AA meter scale
  2. BA vernier calliper where the 10 divisions in vernier scale matches with 9 division in main scale and main scale has 10 divisions in 1 cm
  3. CA screw gauge having 100 divisions in the circular scale and pitch as 1 mm
  4. DA screw gauge having 50 divisions in the circular scale and pitch as 1 mm
Show answer and solution

Answer: (B)

The reading is given to , so the least count is . A meter scale reads to . The vernier described has least count . The screw gauges read to and . So it is the vernier calliper.

Open question: A student measured the length of a rod and wrote it as...

JEE Main 201219 May

Single correct optionMarks +4, -1
divisions on the main scale of a vernier calliper coincide with divisions of the vernier scale. If each division of main scale is '' units, then the least count of the instrument is
  1. A
  2. B
  3. C
  4. D
Show answer and solution

Answer: (D)

vernier divisions equal main scale divisions, so one vernier division is . Least count .

Open question: N divisions on the main scale of a vernier calliper...