Virtual lab

Redox Titration Simulator: Permanganate, Iodometry and Iodimetry

Six redox titrations as films: permanganate as its own indicator, iodometry and iodimetry with starch. See which particle reacts with which, how many of each, and why the colour stays at the end point.

By Sunil Kumar. Updated 26 November 2026.

The film loads here. It needs JavaScript.

How to use the film

  1. Pick an experiment from the row of buttons.
  2. Press Play. The film runs step by step, and the caption beside it says what is happening and why.
  3. Pause at any time. Back and Next move one step. Tap a bar under the picture to jump to that step. Speed changes how fast the film runs.
  4. Drag the slider to add the titrant yourself: the flask, the particles and the graph follow your hand.
  5. After the film, press Give me an unknown. Find its end point and work out the molarity; the bench checks it.

The 6 titrations

1. Permanganate: oxalic acid with

Find the molarity of the oxalic acid. The flask already holds dilute sulphuric acid and is warmed to 60 to 70 degrees C.

Relation: (n-factor: 5, oxalic acid 2)

  • Permanganate is its own indicator: the first drop in excess leaves a pale pink that stays.
  • The first drops lose their colour slowly. The formed then speeds the reaction up (autocatalysis).
  • Read the top of the meniscus: the solution is too dark to see the bottom.

2. Permanganate: Mohr's salt with

Find the molarity of the ferrous ammonium sulphate (Mohr's salt). The flask already holds dilute sulphuric acid. No heating is needed.

Relation:

  • The acid must be sulphuric acid: hydrochloric acid is itself oxidised by permanganate, and nitric acid is an oxidising agent.
  • Do not heat: hot ferrous solution is oxidised by air.

3. Iodometry: copper sulphate with thiosulphate

Find the molarity of the copper sulphate. Add excess potassium iodide first; the iodine set free is then titrated.


Relation: , so

  • Iodometry is indirect: an oxidising agent sets iodine free from iodide, and the iodine is titrated.
  • Add starch only when the brown has faded to pale straw yellow. Added early, starch holds the iodine and the end point drags.
  • At the end point the blue goes and white cuprous iodide is left.

4. Iodometry: potassium dichromate with thiosulphate

Find the molarity of the potassium dichromate. Add acid and excess potassium iodide first; the iodine set free is then titrated.


Relation: , so

  • One dichromate ion takes six electrons, so it sets free three molecules of iodine.
  • At the end point the blue changes to the light green of , not to colourless.

5. Iodimetry: thiosulphate with standard iodine

Find the molarity of the sodium thiosulphate by direct titration with a standard iodine solution.


Iodine dissolves in potassium iodide as

Relation:

  • Iodimetry is direct: a reducing agent is titrated with standard iodine.
  • Here starch goes in at the start: there is no free iodine until the end point, where the first excess drop turns the flask blue.

6. Iodimetry: vitamin C with standard iodine

Find the molarity of the ascorbic acid (vitamin C) by direct titration with a standard iodine solution.

Relation:

  • Ascorbic acid loses two hydrogen atoms: one mole reduces one mole of iodine.
  • Add starch at the start and stop at the first blue that stays.

Iodometry and iodimetry: the difference

IodometryIodimetry
Kindindirectdirect
What is analysedan oxidising agent (, , , bleaching powder)a reducing agent (, , , vitamin C)
What happensthe sample sets iodine free from excess ; the iodine is titrated with thiosulphatethe sample is titrated with a standard iodine solution
Starchadded near the end, at pale straw yellowadded at the start
End pointblue disappearsblue appears

More of the virtual lab